    In 7.1.2,

    CHANGE

    "The pullup gate can have only strength1 specification;
    strength0 specification shall be optional.
    The pulldown gate can have only strength0 specification;
    strength1 specification shall be optional.
    See 7.8 for more details."

    TO

            “The pullup gate shall have one of the following: no strength specification, only a strength1 specification, or both strength1 and strength0 specifications. The pulldown gate shall have one of the following: no strength specification, only a strength0 specification, or both strength1 and strength0 specifications. See 7.8 for more details."”
    http://boydtechinc.com/cgi-bin/issueproposal.pl?cmd=view&database=default&pr=645